Megaman MM27442

MM27442

After check testing which measured an 11% lower average useful luminous flux the Megaman MM27442 was escalated to further testing.  A batch of 20 samples was tested by the project.

Results

Megaman MM27442

Measurements on the higher sample size confirmed the check test finding.  Despite achieving its declared energy class, measured useful luminous flux was 14% lower than claimed (against a 10% tolerance threshold).  A further non-conformity was seen in the luminous intensity, as the average candela measured was only 69% of the claimed value; 1194/2012 states this must achieve at least 75% of the declaration.

Manufacturer response

MarketWatch has communicated the test findings to Megaman, but has yet to receive a response.

Test Report

Energy Label

Rating System

Country: /

test date: January 2016

Tested by: Laborelec

Energy Label Class

a

Declared

a

Measured

Lumen Output (lm)

360

Declared

308

Measured